3 Best Practices for Improved Temperature Management at your Data Center

3 Best Practices for Improved Temperature Management at your Data Center

Jun 25th 2020

Modern data centers are evolving into significant energy add-on values. Research practices are continually going on to devise a way in which they can reduce cooling costs. While it is essential to ensure the smooth functioning of the servers, the high energy consumption that occurs as a result of cooling is also harmful to the environment. IT sectors are focusing on cooling solutions while devising new methods of minimizing the airflow inefficacies.

What is the need for Temperature Management?

The modification in the servers is taking place so that they release less heat. This will subsequently lead to a reduction in the cooling cost of the data centers.

To reduce the cost of cooling, several things can be done. Robert Sullivan had introduced the concept of hot aisle and cold aisle data centers many years ago. He believed that it is the time to embrace the data centers with new  12u wall mount rack methods of cooling.

What are the new Methods of Cooling the Data Centers?

Hot and cold aisle containment: The use of containments can drastically improve the hot air dynamics of the data center, especially when you shut down the hot and cold aisles. You can set your cooling systems to a higher supply temperature, which will automatically save energy and increase the cooling capacity.

Their extended-term benefits are undeniable and are fantastic, although it might lead to an increase in the setup cost. They seal the air gaps between the racks as well as within the racks meticulously. In general, they keep the cooling system of room-oriented temperature much lower to avoid hot spots.

High server rack perforation

The optimum temperature in your data center can be maintained by ensuring that the racks and even their doors do not interfere with the airflow of the room. Optimum temperature can be achieved if the shelves and doors of your server racks are placed in high perforation.

Practices to control the temperature in 12U and 6U mounted racks

You can maintain your data center by integrating them with the environment of your IT infrastructure. You can see an operational gain, which is an advantage for your data center. It provides you with global 24/7 hrs of support. It is always better to keep the measurement of  12u wall mount rack below six temperature sensors for each rack. The intake of temperature must be between 18°-27°C/64°-80°F. The outtake of temperature must be less than 20°C/35°F in contrast to the intake temperature.

How can you make use of Data Server racks?

Data server racks are very efficient and help you to work effectively without any hassle. It is specially developed for IT departments to make their work easier. You can get data server racks of different shapes and sizes. It is measured in rack units. If you are interested in buying a 12u or 6u wall mount rack product, visit Rising Racks for the latest  server wall mount racks.